Control of DFIG-based wind power generation system under unbalanced grid voltage conditions
DOI:
https://doi.org/10.47264/idea.nasij/5.1.7Keywords:
Wind energy, Wind turbines, Power converter, Power fluctuations, Imbalanced grid voltage, Grid disturbances, Doubly fed induction generator, Power rating limitationAbstract
Doubly Fed Induction Generator (DFIG)-based wind turbines have become increasingly popular in recent years due to their capacity to operate at varying speeds. Weaknesses in the DFIG system can arise from issues with the power grid due to the stator's direct connection and the excitation converter's power rating limitation. Under situations of unbalanced grid voltage, this study aims to explore the efficacy of the Direct Power Control (DPC) approach in managing wind turbine systems based on DFIG. Throughout the experimental investigation, we evaluated the system in standard and unbalanced grid voltage settings. MATLAB/SIMULINK simulations implement DPC, specifically tailored for a 9 MW DFIG-based wind farm. The results of these simulations show that the changed control method effectively reduces torque oscillations by making it possible to create active and reactive power references for the rotor-side converter. This eliminates the requirement for sequence component excitation, which was previously necessary. Furthermore, the research highlights the intrinsic link between control techniques and grid circumstances, showing this connectivity's crucial role in improving wind energy systems' stability and operational efficiency based on DFIG.
References
Abed, N. Y., Kabsha, M. M., & Abdlsalam, G. M. (2013). Low voltage ride-through protection techniques for DFIG Wind Generator. In 2013 IEEE Power & Energy Society General Meeting. https://doi.org/10.1109/pesmg.2013.6673049 DOI: https://doi.org/10.1109/PESMG.2013.6673049
Brekken, T. K. A., & Mohan, N. (2007). Control of a doubly fed induction wind generator under unbalanced grid voltage conditions. IEEE Transactions on Energy Conversion, 22(1), 129–135. https://doi.org/10.1109/TEC.2006.889550 DOI: https://doi.org/10.1109/TEC.2006.889550
Chaudhary, S. K., Teodorescu, R., Rodriguez, P., Kjaer, P. C., & Gole, A. M. (2012). Negative sequence current control in wind power plants with VSC-HVDC connection. IEEE Transactions on Sustainable Energy, 3(3), 535–544. https://doi.org/10.1109/tste.2012.2191581 DOI: https://doi.org/10.1109/TSTE.2012.2191581
Flannery, P. S., & Venkataramanan, G. (2008). A fault tolerant doubly fed induction generator wind turbine using a parallel grid side rectifier and series grid side converter. IEEE Transactions on Power Electronics, 23(3), 1126–1135. https://doi.org/10.1109/TPEL.2008.921179 DOI: https://doi.org/10.1109/TPEL.2008.921179
Flannery, P. S., & Venkataramanan, G. (2009). Unbalanced voltage sag ride-through of a doubly fed induction generator wind turbine with series grid-side converter. IEEE Transactions on Industry Applications, 45(5), 1879-1887. https://doi.org/10.1109/TIA.2009.2027540 DOI: https://doi.org/10.1109/TIA.2009.2027540
González, G. N., De Angelo, C. H., & Aligia, D. A. (2022). A control strategy for DFIG-based systems operating under unbalanced grid voltage conditions. International Journal of Electrical Power & Energy Systems, 142 (Part A), 108273. https://doi.org/10.1016/j.ijepes.2022.108273 DOI: https://doi.org/10.1016/j.ijepes.2022.108273
Hu, J., & He, Y. (2009). Reinforced control and operation of DFIG-based wind-power-generation system under unbalanced grid voltage conditions. IEEE Transactions on Energy Conversion, 24(4), 905–915. https://doi.org/10.1109/tec.2008.2001434 DOI: https://doi.org/10.1109/TEC.2008.2001434
Kearney, J., Conlon, M. F., & Coyle, E. (2009). The integrated control of the rotor side and grid side converters in a DFIG to reduce both power and torque pulsations during network voltage unbalance conditions. In 2009 44th International Universities Power Engineering Conference (UPEC) (pp. 1–5). https://ieeexplore.ieee.org/abstract/document/5429408
Liu, W., Lund, H., & Mathiesen, B. V. (2011). Large-scale integration of wind power into the existing Chinese energy system. Energy, 3(8), 4753–4760. https://doi.org/10.1016/j.energy.2011.05.007 DOI: https://doi.org/10.1016/j.energy.2011.05.007
Miao, Z. (2013). Impact of unbalance on electrical and torsional resonances in power electronic interfaced wind energy systems. IEEE Transactions on Power Systems, 28(3), 3105–3113. https://doi.org/10.1109/tpwrs.2013.2243174 DOI: https://doi.org/10.1109/TPWRS.2013.2243174
Morren, J., Pierik, J. T., Haan, S. W., & Bozelie, J. (2005). Grid interaction of offshore wind farms. Part 1. models for dynamic simulation. Wind Energy, 8(3), 265–278. https://doi.org/10.1002/we.158 DOI: https://doi.org/10.1002/we.158
Nian, H., Song, Y., Zhou, P., & He, Y. (2011). Improved direct power control of a wind turbine driven doubly fed induction generator during transient grid voltage unbalance. IEEE Transactions on Energy Conversion, 26(3), 976–986. https://doi.org/10.1109/tec.2011.2158436 DOI: https://doi.org/10.1109/TEC.2011.2158436
Pena, R., Cárdenas, R., Escobar, E., Clare, J., & Wheeler, P. (2007). Control system for unbalanced operation of stand-alone doubly fed induction generators. IEEE Transactions on Energy Conversion, 22(2), 544–545. https://doi.org/10.1109/TEC.2007.895393 DOI: https://doi.org/10.1109/TEC.2007.895393
Phan, V. T., & Lee, H. H. (2011). Improved predictive current control for unbalanced stand-alone doubly-fed induction generator-based wind power systems. IET Electric Power Applications, 5(3), 275–287. https://doi.org/10.1049/iet-epa.2010.0107 DOI: https://doi.org/10.1049/iet-epa.2010.0107
Salam, I. U., Billah, M., & Maaz, M. (2020). A qualitative analysis of an intelligent use of demand and generation in the microgrid. Natural and Applied Sciences International Journal (NASIJ), 1(1), 21–38. https://doi.org/10.47264/idea.nasij/1.1.3 DOI: https://doi.org/10.47264/idea.nasij/1.1.3
Shehata, E. G. (2023). Improved power control of DFIGs driven by wind turbine under unbalanced grid voltage. Journal of Electrical Engineering & Technology, 19, 325–340. https://doi.org/10.1007/s42835-023-01514-y DOI: https://doi.org/10.1007/s42835-023-01514-y
Tavner, P. J., & Penman, J. (1987). Condition monitoring of electrical machines. Research Studies Press.
Zhou, P., He, Y., Sun, D., & Zhu, J. G. (2008). Control and protection of a DFIG-based wind turbine under unbalanced grid voltage dips. In 2008 IEEE Industry Applications Society Annual Meeting (pp. 1–8). https://doi.org/10.1109/08IAS.2008.276 DOI: https://doi.org/10.1109/08IAS.2008.276
Zhou, P., He, Y., & Sun, D. (2009a). Improved direct power control of a DFIG-based wind turbine during network unbalance. IEEE Transactions on Power Electronics, 24(11), 2465–2474. https://doi.org/10.1109/tpel.2009.2032188 DOI: https://doi.org/10.1109/TPEL.2009.2032188
Zhou, Y., Bauer, P., Ferreira, J. A., & Pierik, J. (2009b). Operation of grid-connected DFIG under unbalanced grid voltage condition. IEEE Transactions on Energy Conversion, 24(1), 240–246. https://doi.org/10.1109/tec.2008.2011833 DOI: https://doi.org/10.1109/TEC.2008.2011833
Zhou, S., Liu, J., Zhou, L., Zhu, Y., & Yang, X. (2013). Sag detection algorithm for dynamic voltage restorer used in wind farms under unbalanced and distorted grid voltage conditions. In 2013 IEEE ECCE Asia Downunder (pp. 601–606). https://doi.org/10.1109/ECCE-Asia.2013.6579160 DOI: https://doi.org/10.1109/ECCE-Asia.2013.6579160
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2024 Nabeel Abdelhadi Mohamed Fahal, Tao Zheng

This work is licensed under a Creative Commons Attribution 4.0 International License.
Please click here for details about the Licensing and Copyright policies of NASIJ.